Performance
|
|
Attenuation
|
•••
|
1:1
|
|
Cable
length
|
•••
|
Approx.
1 m
|
|
Input
C
|
•••
|
40
pF ±6 pF
|
|
Bandwidth
|
•••
|
DC
to 30 MHz, ±3 dB (For probes only)
|
|
Conforming
models
|
•••
|
All
models with BNC for input
|
|
|

|
|
|
|
Performance
|
|
Attenuation
|
•••
|
1:1
|
|
Cable
length
|
•••
|
Approx.
2.0 m
|
|
Input
C
|
•••
|
Approx.
70 pF
|
|
Bandwidth
|
•••
|
DC
to 10 MHz, ±3 dB (For probes only)
|
|
Conforming
models
|
•••
|
All
models with BNC for input
|
|
|

|
|
|
|
Performance
|
|
Attenuation
|
•••
|
1:1
|
|
Cable
length
|
•••
|
Approx.
1.1 m
|
|
Input
C
|
•••
|
44
pF ±6 pF
|
|
Bandwidth
|
•••
|
DC
to 30 MHz, ±3 dB (For probes only)
|
|
Conforming
models
|
•••
|
All
models with BNC for input
|
|
|

|
|

|
|
Performance
|
|
Attenuation
|
•••
|
10:1
|
|
Cable
length
|
•••
|
Approx.
1.5 m
|
|
Input
RC
|
•••
|
10
MW, 12.5 pF ±2 pF
|
|
Bandwidth
|
•••
|
DC
to 100 MHz, ±3 dB (For probes only)
|
|
Conforming
input capacity
|
•••
|
18
to 35 pF
|
|
Conforming
models
|
•••
|
DS-8607•A/8608•A,
DS-8710 To be discontinued once remaining stock is sold; to be
replaced by SS-0120
|
|
|

|
|
|
|
Performance
|
|
Attenuation
|
•••
|
10:1
|
|
Cable
length
|
•••
|
Approx.
1.5 m
|
|
Input
RC
|
•••
|
10
MW, 14 pF ±2 pF
|
|
Bandwidth
|
•••
|
DC
to 100 MHz, ±3 dB (For probes only)
|
|
Conforming
input capacity
|
•••
|
22
to 26 pF
|
|
Conforming
models
|
•••
|
SS-6612
|
|
|

|
|
|
|
Performance
|
|
Attenuation
|
•••
|
10:1
|
|
Cable
length
|
•••
|
Approx.
1.5 m
|
|
Input
RC
|
•••
|
10
MW, 13 pF ±2 pF
|
|
Bandwidth
|
•••
|
DC
to 350 MHz, ±3 dB (For probes only)
|
|
Conforming
input capacity
|
•••
|
14
to 19 pF
|
|
Conforming
models
|
•••
|
SS-5421/5321/5221/5121/5121B
|
|
|

|
|
|
|
Performance
|
|
Attenuation
|
•••
|
10:1
|
|
Cable
length
|
•••
|
Approx.
1.5 m
|
|
Input
RC
|
•••
|
10
MW, 14 pF ±2 pF
|
|
Bandwidth
|
•••
|
DC
to 200 MHz, ±3 dB (For probes only)
|
|
Conforming
input capacity
|
•••
|
14
to 24 pF
|
|
Conforming
models
|
•••
|
SS-5712
|
|
|

|
|
|
|
Performance
|
|
Attenuation
|
•••
|
10:1
|
|
Cable
length
|
•••
|
Approx.
1.2 m
|
|
Input
RC
|
•••
|
10
MW, 15 pF
|
|
Bandwidth
|
•••
|
DC
to 200 MHz, ±3 dB (For probes only)
|
|
Conforming
input capacity
|
•••
|
16
to 24 pF
|
|
Conforming
models
|
•••
|
SS-7821
|
|
|

|
|

|
|
Performance
|
|
Attenuation
|
•••
|
10:1
|
|
Cable
length
|
•••
|
Approx.
1.5 m
|
|
Input
RC
|
•••
|
10
MW, approx. 12.5 pF
|
|
Bandwidth
|
•••
|
DC
to 150 MHz, ±2 dB
|
|
Conforming
input capacity
|
•••
|
18
to 35 pF
|
|
Conforming
models
|
•••
|
SS-7811•P,
SS-7810 DS-9121/9122, DS-8617
|
|
Conforming standard
|
•••
|
CE
|
|
|

|
|

|
|
Performance
|
|
Attenuation
|
•••
|
10:1
|
|
Cable
length
|
•••
|
Approx.
1.5 m
|
|
Input
RC
|
•••
|
10
MW, approx. 14.5 pF
|
|
Bandwidth
|
•••
|
DC
to 100 MHz, ±2 dB
|
|
Conforming
input capacity
|
•••
|
21
to 29 pF
|
|
Conforming
models
|
•••
|
SS-7606,
07, 10, 11
|
|
Conforming
standard
|
•••
|
CE
|
|
|

|
|

|
|
Performance
|
|
Attenuation
|
•••
|
10:1
|
|
Cable
length
|
•••
|
Approx.
1.2 m
|
|
Input
RC
|
•••
|
10
MW, approx. 12 pF
|
|
Bandwidth
|
•••
|
DC
to 500 MHz
|
|
Conforming
input capacity
|
•••
|
13
to 23 pF
|
|
Conforming
models
|
•••
|
TS-81000/80600/8500/8500P,
SS-7840/7840H/7840P/7830/
7830P/7825/7825P
|
|
|

|
|

|
|
Performance
|
|
Attenuation
|
•••
|
10:1
(When 50 W load is connected)
|
|
Cable
length
|
•••
|
Approx.
1 m
|
|
Input
RC
|
•••
|
500
W (When 50
W load is connected), 0.25 pF (Typical)
|
|
Bandwidth
|
•••
|
DC
to 6 GHz
|
|
|
|
|

|
|
|
|
Performance
|
|
Attenuation
|
•••
|
100:1
|
|
Cable
length
|
•••
|
Approx.
1.5 m
|
|
Input
RC
|
•••
|
10
MW, approx. 4 pF
|
|
Bandwidth
|
•••
|
DC
to 100 MHz, ±3 dB (For probes only)
|
|
Conforming
input capacity
|
•••
|
20
to 35 pF
|
|
Maximum
input voltage
|
•••
|
1000
V (DC + AC peak)
|
|
|

|
|
|
|
Performance
|
|
Attenuation
|
•••
|
100:1
|
|
Cable
length
|
•••
|
Approx.
1.5 m
|
|
Inupt
RC
|
•••
|
10
MW, approx. 4 pF
|
|
Bandwidth
|
•••
|
DC
to 100 MHz, ±3 dB (For probes only)
|
|
Conforming
input capacity
|
•••
|
15
to 35 pF
|
|
Maximum
input voltage
|
•••
|
1000
V (DC + AC peak)
|
|
|

|
|

|
|
Performance
|
|
Attenuation
|
•••
|
10:1
|
1:1
|
|
Cable
length
|
•••
|
Approx. 1.5 m
|
|
Input
RC
|
•••
|
10
MW,
13 pF ±2 pF
|
1 MW,
200 pF or less
|
|
Bandwidth
|
•••
|
DC
to 60 MHz,
±3 dB
|
DC
to 6 MHz,
±3 dB
|
|
Conforming
input capacity
|
•••
|
20
to 45 pF
|
-
|
|
Conforming
models
|
•••
|
SS-7804•P/7802, DS-8706, DS-8701
|
|
Conforming
standard
|
•••
|
CE
|
|
|

|
|

|
|
Performance
|
|
Attenuation
|
•••
|
10:1
|
1:1
|
|
Cable
length
|
•••
|
Approx. 1.5 m
|
|
Input
RC
|
•••
|
10
MW,
approx. 15 pF
|
1 MW,
150 pF or less
|
|
Bandwidth
|
•••
|
DC
to 100 MHz,
±2 dB
|
DC
to 6 MHz,
±3 dB
|
|
Conforming
input capacity
|
•••
|
18
to 35 pF
|
-
|
|
Conforming
models
|
•••
|
DS-8608•A/8607•A, DS-8710
|
|
Conforming
standard
|
•••
|
CE
|
|
|

|
|

|
|
Performance
|
|
Attenuation
|
•••
|
10:1
|
1:1
|
|
Cable
length
|
•••
|
Approx. 2 m
|
|
Input
RC
|
•••
|
10
MW,
approx. 16 pF
|
1 MW,
170 pF or less
|
|
Bandwidth
|
•••
|
DC
to 100 MHz,
±3 dB
|
DC
to 3 MHz,
±3 dB
|
|
Conforming
input capacity
|
•••
|
18
to 35 pF
|
-
|
|
Conforming
models
|
•••
|
SL-232
|
|
Conforming
standard
|
•••
|
CE
|
|
|

|
|
|
|
Performance
|
|
Attenuation
|
•••
|
100:1
|
10:1
|
|
Cable
length
|
•••
|
Approx. 1.5 m
|
|
Input
RC
|
•••
|
79
MW,
approx. 8 ±1 pF
|
10
MW,
approx. 23 ±1 pF
|
|
Bandwidth
|
•••
|
DC
to 20 MHz,
±3 dB
|
DC
to 40 MHz,
±3 dB
|
|
Conforming
input capacity
|
•••
|
20
to 40 pF
|
20 to 45 pF
|
|
|

|
•
Connector:
|
BNC
|
|
•
Maximum input voltage:
|
600 V
(DC + AC peak); 10: 1 probe
600 V (DC + AC peak); resistance for probe alone 1: 1 probe
|
|
|
|
|

|

|